Atomic Absorption Spectrophotometer (WFX-110A)
![]() Atomic Absorption Spectrophotometer (WFX-110A) |
Product Description
The patented flame analysis technique adopting oxygen-rich air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses
Automatic hollow cathode lamp changeover. The high performance HCL can be used directly
Auto-changeover and position optimization of integrated flame/graphite furnace atomizer
Auto-ignition, automatic spectral bandwidth selection. Fully automated wavelength scanning and peaking
Light-controlled graphite furnace power supplier, adopting FUZZY-PID temperature control technique and dual curve working mode, ensures fast heating, accurate and stable temperature control and good temperature reproducibility. Temperature auto-correction function provided
Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact
Perfect safety protection measures, alarm and automatic safety protection to fuel gas leakage, air pressure deficiency and abnormal flame extinction; Spray chamber made of explosion-proof material, all-titanium burner and explosion-proof stopper for flame analyses; Alarm and protection function to argon pressure deficiency, insufficient cooling water supply, over-heating and over-current etc. In graphite furnace analyses
Adopting large-scale programmable logic array and Inter IC bus technique and highly reliable adapters for electric design
Easy and flexible WINDOWS operating system, with multi-windows processing technology to observe the signal profile, the measured results and the calibration curve at the same time. Various analytical programs, data, signals and graphics can all be stored for later use
| Main Specification | Wavelength range | 190-900nm |
| Wavelength accuracy | ±0.25nm | |
| Resolution | Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. | |
| Baseline stability | ≤0.004A/30min | |
| Background correction | The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times. | |
| Hollow Cathode Lamps | Lamp turret | 6-lamp turret, fully automated scan and peak-picking. |
| Lamp current adjustment | Automatic adjustment and display. Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA | |
| Lamp power supply mode | Powered by two pulses simultaneously | |
| Optical System | Monochomator | Single beam, Czerny-Turner design grating monochromator |
| Grating | 1800 l/mm | |
| Focal length | 277mm | |
| Blazed Wavelength | 250nm | |
| Spectral Bandwidth | 0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change. | |
| Atomizer | Flame/Graphite | Flame & Graphite Furnace atomizer automatic changeover |
| Detection and Data Processing System | Detector | Photomultiplier with high sensitivity and wide spectral range. |
| Software | Ms-Windows 98/Me operating system | |
| Analytical method | Working Curve Method (1st order and 2nd order fitting), Sensitivity auto-correction, Standard Addition Method. | |
| Concentration | Auto-calculation of concentration and content | |
| Repeatable measurement | Maximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation. | |
| Multi-task function | Sequential measurement of multi-elements in one sample | |
| Condition reading | With model function | |
| Result printing | Measurement data and final analytical report printout, editing with Excel. | |
| Flame Analysis | Burner | 10cm single slot all-titanium burner |
| Spray chamber | All-plastic spray chamber. | |
| Nebulizer | High efficiency glass nebulizer with metal sleeve. | |
| Position adjustment | Adjusting mechanism for vertical, horizontal positions and the rotation angle of the burner. | |
| Protection for gas system | Fuel gas leak protection, abnormal flame extinction alarm, air-pressure deficiency protection and explosion-proof device. | |
| Flame ignition | Automatic | |
| Characteristic Concentration and Detection Limit | Normal Air-C2H2 flame | Cu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L; |
| Oxygen-rich Air-C2H2 flame | Ba: Characteristic concentration ≤ 0.22mg/L Al: Characteristic concentration ≤ 0.4mg/L | |
| Hydride generation | Hg: detection limit≤0.5ug/L | |
| Graphite Furnace Analysis | Temperature range | 20~3000ºC |
| Light-controlled temperature range | 1500ºC -3000ºC, temperature auto-correction | |
| Temperature control accuracy | ≤1% | |
| Heating rate | 2000ºC/s | |
| Characteristic mass | Cd≤0.5 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g | |
| Precision | RSD≤4% | |
| Safety protection | Protections for over-heating, over-current, and less cooling water and argon pressure monitoring functions | |
| Power Supply | 220V, 200W | |
| Dimensions | 1020 (L) × 492 (W) × 537 (H) mm (main unit) | |
| 420 (L) × 420 (W) × 460 (H) mm (graphite furnace) | ||
| Weight | Unpacked 80kg (main unit), 50kg (graphite furnace) | |
| Trademark: | UNICOM-OPTICS or Neutral English |
| Model NO.: | WFX-110A |
| Productivity: | 500pcs/year |
| Unit Price/Payment: | FOB USD24,500.00/pc |
| Packing: | Carton or boarding ark |
| Min. Order: | 1 |
| Transportation: | By air or by sea |
| Company: | Tsingtao Unicom-Optics Instruments Co., Ltd. |
Most Popular
-

Gas Permeation Instrument Gas Permeation Instrument is applicable in gas ... -

PH/TDS/EC/CF/ORP Thermometer Monitor PH/TDS/EC/CF/ORP Thermometer Monitor Range: ... -

Precision Sheet Metal Name: Precision Sheet Metal Computer Case, ...
-

Schenck Vertical Balancing Machine-HV Balance Machine Vertical balancing machine Simple operation ... -

Process Explosion-Proof Trace Oxygen Analyzer (GNL-B) Introduction GNL-B oxygen analyzer is an online ... -

PH Meter Hongkong and Shanghai Total Co., Ltd. is ...
-

LCR Meter, LCZ Meter, LCR Tester Description: 1061/1062/1063 LCZ Meters are a ... -

Process Oxygen Analyzer (GNL-6000) Introduction GNL-6000 oxygen analyzer is the ... -

Schenck Horizontal Balancing Machine-HM1/HM10 Balance ... Horizontal Balancing Machine Modular structure ...
-

Portable High Purity Oxygen Analyzer (GNL-2100L) Introduction GNL-2100L Oxygen analyzer breaks ... -

Schenck Balancing Machine for crankshafts-balancing ... Balancing machine for crankshafts Modular ...
Quick Products |
Inquiry Basket (