Atomic Absorption Spectrophotometer (WFX-110A)

Atomic Absorption Spectrophotometer (WFX-110A)
Atomic Absorption Spectrophotometer (WFX-110A)

Product Description

The patented flame analysis technique adopting oxygen-rich air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses

Automatic hollow cathode lamp changeover. The high performance HCL can be used directly

Auto-changeover and position optimization of integrated flame/graphite furnace atomizer

Auto-ignition, automatic spectral bandwidth selection. Fully automated wavelength scanning and peaking

Light-controlled graphite furnace power supplier, adopting FUZZY-PID temperature control technique and dual curve working mode, ensures fast heating, accurate and stable temperature control and good temperature reproducibility. Temperature auto-correction function provided

Graphite furnace with pneumatic control and pressure lock ensures constant pressure and reliable contact

Perfect safety protection measures, alarm and automatic safety protection to fuel gas leakage, air pressure deficiency and abnormal flame extinction; Spray chamber made of explosion-proof material, all-titanium burner and explosion-proof stopper for flame analyses; Alarm and protection function to argon pressure deficiency, insufficient cooling water supply, over-heating and over-current etc. In graphite furnace analyses

Adopting large-scale programmable logic array and Inter IC bus technique and highly reliable adapters for electric design

Easy and flexible WINDOWS operating system, with multi-windows processing technology to observe the signal profile, the measured results and the calibration curve at the same time. Various analytical programs, data, signals and graphics can all be stored for later use

Main SpecificationWavelength range190-900nm
Wavelength accuracy±0.25nm
ResolutionTwo spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.
Baseline stability≤0.004A/30min
Background correctionThe D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times.
Hollow Cathode LampsLamp turret6-lamp turret, fully automated scan and peak-picking.
Lamp current adjustmentAutomatic adjustment and display. Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA 
Lamp power supply modePowered by two pulses simultaneously 
Optical SystemMonochomatorSingle beam, Czerny-Turner design grating monochromator
Grating1800 l/mm
Focal length277mm
Blazed Wavelength250nm
Spectral Bandwidth0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change.
AtomizerFlame/GraphiteFlame & Graphite Furnace atomizer automatic changeover
Detection and Data Processing SystemDetectorPhotomultiplier with high sensitivity and wide spectral range.  
SoftwareMs-Windows 98/Me operating system
Analytical methodWorking Curve Method (1st order and 2nd order fitting), Sensitivity auto-correction, Standard Addition Method.
ConcentrationAuto-calculation of concentration and content
Repeatable measurementMaximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation.
Multi-task functionSequential measurement of multi-elements in one sample
Condition readingWith model function
Result printingMeasurement data and final analytical report printout, editing with Excel.
Flame AnalysisBurner10cm single slot all-titanium burner
Spray chamberAll-plastic spray chamber.
NebulizerHigh efficiency glass nebulizer with metal sleeve.
Position adjustmentAdjusting mechanism for vertical, horizontal positions and the rotation angle of the burner.
Protection for gas systemFuel gas leak protection, abnormal flame extinction alarm, air-pressure deficiency protection and explosion-proof device.
Flame ignitionAutomatic
Characteristic Concentration and Detection LimitNormal Air-C2H2 flameCu: Characteristic concentration≤0.025mg/L, Detection limit≤0.006mg/L;
Oxygen-rich Air-C2H2 flameBa: Characteristic concentration ≤ 0.22mg/L Al: Characteristic concentration ≤ 0.4mg/L
Hydride generationHg: detection limit≤0.5ug/L
Graphite Furnace AnalysisTemperature range20~3000ºC
Light-controlled temperature range1500ºC -3000ºC, temperature auto-correction
Temperature control accuracy≤1%
Heating rate2000ºC/s
Characteristic massCd≤0.5 ×10-12g, Cu≤5 ×10-12g, Mo≤1×10-11g
PrecisionRSD≤4%
Safety protectionProtections for over-heating, over-current, and less cooling water and argon pressure monitoring functions
Power Supply220V, 200W
Dimensions1020 (L) × 492 (W) × 537 (H) mm (main unit)                 
420 (L) × 420 (W) × 460 (H) mm (graphite furnace)
WeightUnpacked 80kg (main unit), 50kg (graphite furnace)
Trademark: UNICOM-OPTICS or Neutral English
Model NO.: WFX-110A
Productivity: 500pcs/year
Unit Price/Payment: FOB USD24,500.00/pc
Packing: Carton or boarding ark
Min. Order: 1
Transportation: By air or by sea
Company: Tsingtao Unicom-Optics Instruments Co., Ltd.

Click here to send inquiry