Ion Chromatography (IC-100PRO)
![]() Ion Chromatography (IC-100PRO) |
Product Description
Designed specifically for routine analysis that increases sample throughput.
Contamination-free with inert material throughout the fluidic flow path.
High performance from digital, thermally controlled conductivity detection.
For improved reproducibility, the heated and thermostatted high-performance conductivity detection cell permits measurements that are unaffected by temperature variations. This capability allows the instrument to provide sensitive conductivity results consistently, without variations in baseline drift. Advanced single-range digital output provides a full range for your ion analysis needs. Whether in low or high concentrations, ions of interest are easily identified in this detection range.
IC-100PRO adopts complete polymeric systems constructed of PEEK materials. Metal-free materials prevent the acid and base mobile phases traditionally used in IC analysis from contaminating and corroding the system. The PEEK material used provides a chemically inert pump and system flow path compatible with aqueous eluents of pH 0-14. Maintaining your system is simplified with materials that do not promote problems in the system. You can expect lower maintenance cost with the use of factory-equipped piston seal wash. This standard feature protects the dual-piston pumping system between routine maintenance cycles by rinsing the pistons and rear seals continuously with DI water. The PEEK tubing used to plumb the system is easy to use and cut for fast replacement or plumbing flexibility. The IC-100PRO are configured and ready for your most challenging anion or cation analysis.
For improved reproducibility, the heated and thermostatted high-performance conductivity detection cell permits measurements that are unaffected by temperature variations. This capability allows the instrument to provide sensitive conductivity results consistently, without variations in baseline drift. Advanced single-range digital output provides a full range for your ion analysis needs. Whether in low or high concentrations, ions of interest are easily identified in this detection range.
| Type | Serial dual-reciprocating pistons, microprocessor-controlled constant stroke, variable speed |
| Construction | Chemically inert, metal-free PEEK pump heads and flow paths compatible with aqueous eluents of pH 0–14 and reversed-phase solvents |
| Control mode | Full control through front panel |
| Maximum operating pressure | 45 MPa |
| Pressure ripple | <1.0 % from 0.4 to 2.0 mL/min at 1000–3000 psi |
| Flow rate range | 0.01–9.99 mL/min in 0.01 increments, typical operating range is 0.4–2.0 mL/min |
| Flow precision | ± 0.1 % |
| Flow accuracy | ± 0.05 % |
| System Flow Constancy | Typically < 0.1 % |
| Piston seal wash | Dual-pump head, wash can be continuous when connected to rinse solution supply |
| Pressure alarm limits | Upper limit 0–45 MPa or 0–6400 psi in one unit (MPa or psi) increments, lower limit can be set up to one unit lower than upper limit |
2. Conductivity Detector
| Type | Microprocessor-controlled digital signal processor |
| Cell drive | 8-kHz square wave |
| Linearity | 1% at 1 ms |
| Resolution | 0.1 ns |
| Full-scale output ranges | Digital signal range: 0–15,000 µs Analog signal range: 0–15,000 µs |
| Electronic noise | ±0.1 ns when background conductivity is 0–150 µs ±2 ns when background conductivity is 151–3200 µs |
| Filter | Rise times from 0 to 10 s, user selectable |
| Temperature compensation | Fixed at 1.7% per 1 ºC at cell temperature |
| Temperature range | Ambient +7 ºC to 55 ºC |
| Temperature stability | < 0.01 ºC |
| Cell electrodes | Passivated 316 stainless steel |
| Cell body | Chemically inert polymeric material |
| Cell volume | <1.4 µL |
| Heat exchanger | Low dispersion |
| Maximum cell operating pressure | 2 MPa (300 psi) |
| Suppressor control | Self-Regenerating electrolytic Suppressor AES, 0–150 mA in 1-mA increments SRS, 0–500 mA in 1-mA increments |
| Separating capacity | Analyze F - , Cl - , NO 2 - , PO 4 3- , Br - , NO 3 - , SO 4 2- , ClO 2 - , ClO 3 - , BrO 3 - in 16 minutes. Analyze Li + , Na + , NH 4 + , K + , Mg 2+ , Ca 2+ , Sr 2+ , Ba 2+ in 20 minutes. |
| Lower limits of detection | <0.1ug/L (CI - ), 3ug/L (Na + ) |
| Linear limits | > 10 3 |
| Linear correlation coefficient | > 0.995 |
| RSD% | < 1.5% (measured by SO 4 2- ) |
3. Column
| AN serial ion exchange column Alltech serial ion exchange column |
4. Workstation
| Input range: -1.3V--+1.3V Sensitivity: 0.05uV.S Frequency: 6000 |
5. Physical Specifications
| Display | Large touch-sensitive LCD display |
| Power requirements | 220V±10% 50Hz / 110V±10% 60Hz |
| Operating temperature | 15–30 ºC |
| Operating humidity range | 5–85% relative, noncondensing |
| Control mode | Full control through front panel |
| Communication protocol | RS232-USB port |
| Dimensions (h × w × d) | 56.1 × 22.4 × 53.3 cm (22.1 × 8.8 × 21 in.) |
| Weight | 24.5 kg (54 lb) |
Packing List for IC-100PRO Ion Chromatography
| NO. | Name | Type | Unit | Quantity |
| 1 | Main processor | IC-100 | 1 | |
| 2 | O type sealing washer | Φ4.5×1.5 | 30 | |
| 3 | Simulated conductance board | 1 | ||
| 4 | Conical column tie-in | 4 | ||
| 5 | Four fluorin pipeline | Φ1.5 | Meter | 3 |
| 6 | Electric iron | 20W | 2 | |
| 7 | Flanging tip | 2 | ||
| 8 | Injector | 2ml | 10 | |
| 9 | Syringe needle | 10 | ||
| 10 | Blown fuse | 2A | 10 | |
| 11 | Lever | 100×12 | 1 | |
| 12 | Blade | One-edged | 2 | |
| 13 | Long nosed pliers | 150mm | 1 | |
| 14 | Screwdriver | 1 | ||
| 15 | Power cord | 2 | ||
| 16 | Instruction manual | 1 | ||
| 17 | Flow pipeline joint | M6 | 8 | |
| 18 | Inhibitor | Self-regenerate | 1 | |
| 19 | Anion chromatographic column | 1 | ||
| 20 | Chromatography working station | Including disk, signal line, manual | Set | 1 |
| 21 | Certificate of quality | 1 | ||
| 22 | Constant loaded resistance | 100Ω | 5 | |
| 23 | Pump accessories | Bag | 1 |
| Trademark: | Neutral English |
| Model NO.: | IC-100PRO |
| Productivity: | 1, 000pcs/year |
| Unit Price/Payment: | FOB USD23, 500.00/pc |
| Origin: | Tsingtao |
| Packing: | Carton or boarding ark |
| Min. Order: | 1 |
| Transportation: | By air or by sea |
| Company: | Tsingtao Unicom-Optics Instruments Co., Ltd. |
Other products from this company
Most Popular
-

Portable High Purity Oxygen Analyzer (GNL-2100L) Introduction GNL-2100L Oxygen analyzer breaks ... -

Schenck Field Balancing Machine - Smart Balancer Field balancing-portable balancing machine A ... -

Oxygen Permeation Instrument Oxygen permeation instrument determines to test ...
-

Precision Sheet Metal Name: Precision Sheet Metal Computer Case, ... -

LCR Meter, LCZ Meter, LCR Tester Description: 1061/1062/1063 LCZ Meters are a ... -

PH/TDS/EC/CF/ORP Thermometer Monitor PH/TDS/EC/CF/ORP Thermometer Monitor Range: ...
-

PH Meter Hongkong and Shanghai Total Co., Ltd. is ... -

Schenck Horizontal Balancing Machine (HM1/HM10) Horizontal Balancing Machine Modular structure ... -

Process Oxygen Analyzer (GNL-6000) Introduction GNL-6000 oxygen analyzer is the ...
-

Fogging Tester (DIN 75201) Fogging Tester is applicable in fogging test of ... -

Process Explosion-Proof Trace Oxygen Analyzer (GNL-B) Introduction GNL-B oxygen analyzer is an online ... -

Schenck Horizontal Universal Balance Machine (PASIO50) Horizontal universal balancing machine for rotors ...
-

Gas Analyzer (HGA-01) Headspace Gas Analyzer is used for the ...
Quick Products |
Inquiry Basket (





