Gas Chromatography (GC9790II)
![]() Gas Chromatography (GC9790II) |
Product Description
TSINGTAO UNICOM-OPTICS GC9790Series Gas Chromatographs are new generation products. Instruments adopt the most advanced microcomputer control system and large LCD with both Chinese and English display. Carry out all control and analysis on PC. Built-in A/D converter is available for option, Chromatography signal output digitally. High liable and high sensible micro current amplifier heightens the FID detection limit. New model TCD detection sensibility heightens 5 times than common TCD.
. Capillary and packed column inlets, split and splitless, cool-on-column
. Programmable oven, 8 ramps temperature programming, 6 temperatures, up to 400º C
. Wide dynamic range of popular detectors: FID, TCD, NPD, ECD and FPD
. Instrument control, method setup and run from keyboard entries
. Rugged manual injection and manual pneumatics
. Self-diagnosis of controls: Thermal zone, flows, and detectors
. Ready to use when product delivered and installed
. Unbeatable price and service package
. Guarantee timely and no-hassle service responding
. Dual pneumatics
| Dual packed column inlets | |
| GC9790IIF | Dual FID Detector |
| GC9790IIT | TCD Detector |
| GC979IIT-2 | TCD Detector (new type) |
| GC9790IIP | FPD Detector |
| GC9790IIE | ECD Detector |
| GC9790IIG | Dual FID Detector, dual amplified board |
| GC9790IIB | Dual FID Detector, TCD Detector |
| GC9790IIB-2 | Dual FID Detector, TCD Detector (new type) |
| GC9790IID | FID Detector, FPD Detector |
| GC9790IIK | Dual FID Detector, ECD Detector |
| GC9790IIH | TCD Detector, FPD Detector |
| GC9790IIL-3 | Dual FID Detector, ECD Detector, FPD Detector |
| Packed column inlet, Capillary column inlet (split and splitless) | |
| GC9790IIJ | Dual FID Detector |
| GC9790IIR | FID Detector, NPD Detector |
| GC9790IIC | Dual FID Detector, dual FID amplified board |
| GC9790IIA | Dual FID Detector, TCD Detector |
| GC9790IIA-2 | Dual FID Detector, TCD Detector (new type) |
| GC9790III | FID Detector, FPD Detector |
| GC9790IIL | Dual FID Detector, ECD Detector |
| GC9790IIL-2 | FID Detector, ECD Detector, FPD Detector |
| GC9790IIL-4 | FID Detector, ECD Detector, NPD Detector |
| GC9790IIL-5 | FID Detector, NPD Detector |
| GC9790IIL-6 | FID Detector, ECD Detector, NPD Detector |
| Dual Capillary column inlets (split and splitless) | |
| GC9790IIQ | Dual FID Detector |
| GC9790IIN | Dual FID Detector, dual amplified board |
Detector: FID
| Detection limit | ≤3x10 -12 g/s |
| Sensitivity Mv.ml/mg[n-C16] | |
| Noise | ≤3x10 -14 A |
| Drift | ≤5x10 -13 A/30min |
| Linear range | ≥10 6 |
Detector: TCD
| Detection limit | |
| Sensitivity Mv.ml/mg[n-C16] | ≥2500 |
| Noise | ≤20μV |
| Drift | ≤100μV/30min |
| Linear range | ≥10 4 |
Detector: TCD(new type)
| Detection limit | |
| Sensitivity Mv.ml/mg[n-C16] | ≥8000 |
| Noise | ≤20μV |
| Drift | ≤100μV/30min |
| Linear range | ≥10 4 |
Detector: ECD
| Detection limit | ≤1x10 -13 g/ml |
| Sensitivity Mv.ml/mg[n-C16] | |
| Noise | ≤20μV/30min |
| Drift | ≤50μV/30min |
| Linear range | ≥10 4 |
Detector: FPD
| Detection limit | Mt≤1.4x10 -12 g/s(P), Mt≤5x10 -11 g/s(S) methyl parathion |
| Sensitivity Mv.ml/mg[n-C16] | |
| Noise | ≤4x10 -10 A |
| Drift | ≤4x10 -10 A/30min |
| Linear range | ≥10 3 (P), ≥10 2 (S) |
Detector: NPD
| Detection limit | |
| Sensitivity Mv.ml/mg[n-C16] | Mt≤5x10 -13 g/s(N) Malathion, Mt≤1x10 -12 g/s(P) azobenzol |
| Noise | ≤4x10 -13 A/30min |
| Drift | ≤2x10 -12 A/30min |
| Linear range | ≥10 3 |
More Product Features
| HS Code: | 90272019 |
| Trademark: | Neutral English |
| Model NO.: | GC9790IIB-2 |
| Standard: | ISO |
| Productivity: | 1,000 pcs/year |
| Unit Price/Payment: | FOB USD7,500.00/pc |
| Packing: | Carton |
| Min. Order: | 1 |
| Transportation: | By Air or by Sea |
| Company: | Tsingtao Unicom-Optics Instruments Co., Ltd. |
Other products from this company
Most Popular
-

BGB-B Series High Efficiency Film Coating Machine The BGB-B Series high efficiency film coating ... -

Titanium Steel Storage Tank 1)Equipment Name: Titanium Steel Storage ... -

Cooling Tower 1) Good shape with small outside size, light ...
-

EDM Machine (EDM450) (1) Main performance indexes and technical ... -

Full Notch Creep Tester FNCT is a method of determining the stress ... -

Double Sides Automatic Labeling Machine (RGTBD-02) Introduction: This machine is suitable for ...
-

Ceramic Ring-P (Equivalent to Pall Ring) Our standard ring series random packings ... -

The Machine Auto Production Line of the GL-5 Series Stem ... Characteristic of configuration: 1. The host ... -

Latest 3-Efficient Energy-Saving Concentrator ... SJN-500B-8000B Type latest 3-efficient ...
-

Alcohol Distill Machinery(WZJN-SERIES) The equipment is applicable to the alcohol ... -

Pelletizer Summary: The pelletizer is used to press powder ... -

Multi-Function Dry Machine Set (500L-5000L) Description: 1 Summarization This ...
-

Manual Paint Dispenser with Stainless Steel Canisters ... This manual paint dispenser has 12, 14, 16, 20 ... -

Ambient Air Vaporizer (VAN Series) INTRODUCTION: This serial vaporizer uses ... -

Parts for Pegasus (M600-L31) (208192-92) Parts for pegasus M600-L31 (208192-92)
Quick Products |
Inquiry Basket (